懸浮物污泥濃度計由變送器和傳感器組成,為了更實時有效地監測懸浮物污泥濃度指標,懸浮物污泥濃度計具體安裝的監測點一般如下:1.預濃縮池和濃縮池上方,實時監測排放水懸浮物指標;2.雨水房,用以監測最終排入河道的排放水懸浮物指標;3.平衡池上方,實時監測平衡池內污泥濃度指標。根據以上安裝監測點的選型要求,選用我司量程為0-50g/L懸浮物污泥濃度分析儀可檢測濁度,也可以檢測懸浮物及污泥濃度值,并且探頭可配置自動清洗功能根據預先設置的時間自動定時清洗,從而大大降低了儀器維護的工作量。下面小編就先帶大家來詳細的了解下懸浮物污泥濃度計(變送器和傳感器)安裝(zhuang)位置相關信(xin)息如下:
懸浮(fu)物污泥(ni)濃度計變(bian)送器的安裝:
1、在選擇變(bian)(bian)送(song)(song)(song)器(qi)安(an)裝位置時,需要遵循如下原則:避(bi)(bi)免變(bian)(bian)送(song)(song)(song)器(qi)受陽光直射;避(bi)(bi)免使(shi)變(bian)(bian)送(song)(song)(song)器(qi)產生過多震動(dong);如果情況允許,應(ying)將(jiang)變(bian)(bian)送(song)(song)(song)器(qi)安(an)裝于稍(shao)(shao)稍(shao)(shao)高于操(cao)作者平(ping)視水(shui)平(ping)的(de)位置,這樣將(jiang)會有利于操(cao)作者可以(yi)非常(chang)舒服(fu)地(di)瀏(liu)覽前部面板和進行控制操(cao)作,為變(bian)(bian)送(song)(song)(song)器(qi)箱體的(de)開啟和維護留出足(zu)夠的(de)空(kong)間。
2、壁掛(gua)式(shi)變送(song)器(qi)背后(hou)有(you)三個孔(kong),其中上面的孔(kong)用于懸掛(gua),下(xia)面兩(liang)個孔(kong)用于加螺栓(shuan)固定。盤裝式(shi)變送(song)器(qi)背后(hou)有(you)四個螺栓(shuan)或兩(liang)組卡扣,方便固定于墻面或儀(yi)表箱面板。
懸(xuan)浮物(wu)污(wu)泥濃度計傳(chuan)感器的(de)安裝:
1.為確保(bao)測(ce)量(liang)準確,在(zai)選擇傳感器安(an)裝位置(zhi)時,需(xu)要遵循如下標準:應將傳感器安(an)裝在(zai)工(gong)藝的(de)恰當位置(zhi),以保(bao)證獲得具污泥濃(nong)度計是為測(ce)量(liang)市政污水(shui)或工(gong)業廢水(shui)處理過程(cheng)中(zhong)懸(xuan)浮物(wu)濃(nong)度而設計的(de)有(you)代表性的(de)測(ce)量(liang)結果,且安(an)裝位置(zhi)應該便于操(cao)作(zuo)者進行取樣操(cao)作(zuo),傳感器和取樣點之(zhi)間的(de)距離(li)推薦最大(da)值不超過1.5m。不正確的(de)取樣操(cao)作(zuo)是導致(zhi)測(ce)量(liang)數(shu)據有(you)誤的(de)一個常見(jian)原因;
2.應(ying)將(jiang)傳感器安裝在易于觸(chu)及的(de)位置,方便對傳感器進行定期的(de)清洗和維護
3.應避(bi)免將傳感器(qi)(qi)安裝在(zai)氣(qi)泡較(jiao)多(duo)的(de)(de)位置,因(yin)為氣(qi)泡會產生干擾信(xin)號。在(zai)某些(xie)應用條(tiao)件下,氣(qi)泡的(de)(de)產生是難以避(bi)免的(de)(de),例如在(zai)測量離心液或(huo)者(zhe)過(guo)濾液等的(de)(de)應用中,在(zai)這些(xie)情況下應將傳感器(qi)(qi)安裝在(zai)脫氣(qi)裝置內;
4.應將傳感器安裝在工藝(yi)混合良好和(he)不出現(xian)停(ting)機的位置(zhi),這通(tong)常也是取樣點所(suo)在的位置(zhi),傳感器的探頭應該(gai)背向工藝(yi)介質流向。
接下來我們再來了解下懸浮物污泥濃度計的常見安裝方式:
懸浮物污泥濃度計通常有兩種方(fang)式(shi)(shi):浸沒式(shi)(shi)安(an)(an)(an)裝(zhuang)也(ye)(ye)叫(jiao)沉入式(shi)(shi)安(an)(an)(an)裝(zhuang)和(he)流通式(shi)(shi)安(an)(an)(an)裝(zhuang)也(ye)(ye)叫(jiao)管(guan)道式(shi)(shi)安(an)(an)(an)裝(zhuang),可以方(fang)便(bian)地安(an)(an)(an)裝(zhuang)在池內、排水管(guan)、壓(ya)力管(guan)道或(huo)自(zi)然水體中。
浸沒式(沉(chen)(chen)入(ru)式)安裝(zhuang)(zhuang):浸沒式(沉(chen)(chen)入(ru)式)安裝(zhuang)(zhuang)方式是指把傳感(gan)器通過(guo)安裝(zhuang)(zhuang)支(zhi)架浸入(ru)池(chi)(chi)中(zhong)或罐(guan)中(zhong)的安裝(zhuang)(zhuang)方式,通常適合(he)于曝氣池(chi)(chi)、沉(chen)(chen)淀池(chi)(chi)、濃縮池(chi)(chi)、回流渠等場合(he)。
流(liu)(liu)通(tong)(tong)(tong)式(shi)(管道(dao)(dao)式(shi))安(an)裝:流(liu)(liu)通(tong)(tong)(tong)式(shi)(管道(dao)(dao)式(shi))安(an)裝是(shi)指(zhi)管道(dao)(dao)開孔裝一個控制閥門通(tong)(tong)(tong)過指(zhi)定(ding)氣管或軟管連接引流(liu)(liu)接入我們配(pei)置的流(liu)(liu)通(tong)(tong)(tong)池裝置,流(liu)(liu)通(tong)(tong)(tong)池配(pei)有進(jin)水(shui)口(kou)、出水(shui)口(kou)、溢流(liu)(liu)口(kou)和排污口(kou),通(tong)(tong)(tong)過雙向閥門控制水(shui)流(liu)(liu)大小(xiao),保持出水(shui)口(kou)和溢流(liu)(liu)口(kou)穩定(ding)出水(shui),全(quan)過程無需壓(ya)力自流(liu)(liu)就可以,使用(yong)時(shi)間長后如若流(liu)(liu)通(tong)(tong)(tong)池中雜質比較(jiao)多需要清理打(da)開排污口(kou)用(yong)水(shui)沖洗干凈即可。
最后小編想要強調一點重要的信息:當浸沒式(shi)安裝時,傳(chuan)(chuan)感器(qi)(qi)一定要安裝在(zai)(zai)安裝支(zhi)架上,不(bu)可以用(yong)傳(chuan)(chuan)感器(qi)(qi)的電纜將傳(chuan)(chuan)感器(qi)(qi)懸掛在(zai)(zai)水中(zhong),同時需(xu)要注意的是傳(chuan)(chuan)感器(qi)(qi)應(ying)浸沒至(zhi)水面(mian)下(xia)不(bu)小于30cm的深(shen)(shen)度,或者浸沒至(zhi)取樣時通(tong)常(chang)到達的深(shen)(shen)度,并避免陽光直射(she)。